RTMC Real-Time Monitoring and Control Software

Resumen

Versión actual: 5.0

El software RTMC (real-time monitoring and control) forma parte de nuestros paquetes de software LoggerNet, LoggerNet Admin y RTDAQ. RTMC no puede comprarse por separado. Permite mostrar datos en forma gráfica, prefijar valores de variables e input locations, cambiar estado de puertos y banderas del datalogger. RTMC incluye componentes gráficos como alarmas, barra de progreso, gráficos, cambio de estado, tablas, y indicadores que permiten diseñar pantallas personalizadas multi-pestaña. La versión profesional RTMC-Pro dispone de más componentes.

Leer más

Ventajas y características

  • Real-time monitoring and control software bundled with LoggerNet, LoggerNet Admin, and RTDAQ software

Imágenes

Descripción detallada

RTMC Real-time Monitoring and Control Software is bundled with our LoggerNet, LoggerNet Admin, and RTDAQ software. It graphically displays data, sets input locations, and toggles ports and flags. A simple yet powerful user interface allows RTMC to use components such as alarms, sliders, graphs, toggles, tables, and gauges to design custom multi-tab displays.

RTMC's bitmap-based display system provides the tools used to tailor your displays. It can simultaneously display data from any number of data loggers in the network. RTMC can access statistical data reported by the server, including the current state of your data logger network and system-critical information used to trigger alarms. All of RTMC's functions are available when connected as a client to a server on a remote PC. RTMC also includes a sophisticated real-time mathematical compiler for performing real-time calculations. With its point-and-click interface, RTMC is a simple solution for generating real-time displays.

Especificaciones

Current Version 5.0
Operating System Windows 11 or 10 (Both 32- and 64-bit operating systems are supported.)
Purchased Separately No (Bundled with LoggerNet, LoggerNet Admin, and RTDAQ software)
Software Level Entry
Real-Time Updates Yes
Alarms Real-time, visual, audible

Compatibilidad

Nota: lo siguiente muestra información de compatibilidad notable. No es una lista de todos los productos compatibles.

Dataloggers

Producto Compatible Nota
CR1000 (retired)
CR1000X
CR200X (retired)
CR216X (retired)
CR300
CR3000 (retired)
CR310
CR350
CR5000 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR9000X (retired)

Miscelaneo

Producto Compatible Nota
21X (retired)
CR10 (retired)
CR10X (retired) RTMC is compatible with the mixed array, PakBus, and TD data logger operating systems for the CR510, CR10X, and CR23X dataloggers.
CR23X (retired) RTMC is compatible with the mixed array, PakBus, and TD data logger operating systems for the CR510, CR10X, and CR23X dataloggers.
CR500 (retired)
CR510 (retired) RTMC is compatible with the mixed array, PakBus, and TD data logger operating systems for the CR510, CR10X, and CR23X dataloggers.
CR9000 (retired)

Información de compatibilidad adicional

Computer

RTMC runs on Windows 10 and 11. RTMC runs on both 32-bit and 64-bit versions of these operating systems.

Preguntas frecuentes

Número de FAQs relacionadas con RTMC: 24

Expandir todoDesplegar todo

  1. A network may need to be loaded into LoggerNet from a backup file. If there was no backup, an identical network must be set up in the LoggerNet Setup for the RTMC project to run.

  2. Users can control the look of their projects to some extent through Edit | Preferences | Graphics Quality. The default option is High Quality, which uses anti-aliased fonts when rendering text. Lowering the graphic quality changes the text so that it is rendered in more of a block fashion.

  3. In RTMC Pro, add the picture or icon to be used as a hyperlink, and then place a hotspot over it. The HotSpot tool is found in the tool box under Commands.

  4. The project needs to be designed in RTMC Pro using the development environment. The project can then be run within the development environment or by using RTMC Run-Time.

  5. Value forwarders can be used to keep all of the values synchronized. Use the switch to set the value in one datalogger, and then use multiple value forwarders to read this value and forward it on to the other dataloggers. The value forwarders can be set as hidden so that they don’t show up in runtime.

  6. Most controls in RTMC work with mathematical expressions for their fields. For example, if there is a table named one_hour on station stat with a field named temp_degc, an expression can be entered to convert this to degrees Fahrenheit as follows:

    1.8 * "stat.one_hour.temp_degc" + 32

  7. Access the Public table in the datalogger to use SetPoint. By changing the station setup to retrieve the Public table, it should show up in RTMC as being able to read/write to.

  8. Yes. The “Getting Started with RTMC Tutorial” is available for download.

  9. Yes, provided the serial sensor is connected to a port that is separate from the one used to connect to LoggerNet.

  10. RTMC can be used to create real-time time-series plots of many parameters.

Casos de aplicación

South Africa: Launch of an Innovative Science Facility with Sustainable Technology
The Department of Science and Innovation (DSI) and its partners, including the Department of Basic......leer más

Artículos y notas de prensa