Reguladores / PS150
PS150 12 V Power Supply
ETL Listed
Charging regulator with 7 Ah sealed rechargeable battery
meteorología aplicaciones agua aplicaciones energía aplicaciones flujo gas y turbulencia aplicaciones infraestructuras aplicaciones suelo aplicaciones

Resumen

The PS150 is a 12 Vdc power supply that includes a rechargeable 7 Ah valve-regulated lead-acid (VRLA) battery and charging regulator. Charging power for the PS150 is typically supplied by an unregulated solar panel, AC/AC transformer, or AC/DC converter. The PS150 provides charging with temperature compensation for optimal charging and battery life. A maximum power point tracking algorithm is incorporated for solar inputs to maximize available solar charging resources.

Leer más

Ventajas y características

  • Protege contra daños por alto amperaje y alto voltaje
  • Protección contra polaridad invertida de la batería
  • Permite la conexión simultanea de dos fuentes de carga (por ej. panel solar y adaptador 220Vac)
  • Fuente alimentación ETL listed Class 2

Imágenes

PS150 top view
PS150 top view
PS150 top view
PS150 back view
PS150 left view
PS150 right view
PS150 top view
PS150 bottom view

Descripción detallada

The PS150 is a micro-controller-based smart charger with temperature compensation that optimizes battery charging and increases the battery's life. Two input terminals enable simultaneous connection of two charging sources. They also incorporate a maximum power point tracking algorithm for solar inputs that maximizes available solar charging resources.

The PS150 has several safety features intended to protect the charging source, battery, charger, and load devices. Battery-reversal protection is included, as well as ESD and surge protection on all of the PS150 inputs and outputs.

The PS150 replaced the PS100. 

Especificaciones

Operational Temperature -40° to +60°C (VRLA battery manufacturers state that “heat kills batteries” and recommend operating batteries at ≤ 50°C.)
Dimensiones 19.3 x 7.6 x 10.6 cm (7.5 x 3 x 4.2 in.)

CHARGE - CHARGE Terminals (AC or DC Source)

AC 18 to 24 VRMS (internally limited to 1.2 ARMS)
DC 16 to 40 Vdc (internally limited to 0.85 Adc)

SOLAR Terminals (Solar Panel or Other DC Source)

-NOTA- Battery voltages below 8.7 V may result in < 3.0 A current limit because of fold-back current limit.
Rango voltaje entrada 15 to 40 Vdc
Maximum Charging Current 4.0 Adc typical (3.2 to 4.9 Adc depending upon individual charger)

Quiescent Current

No Charge Source Present 160 μA at 13.7 Vdc
No Battery Connected 930 μA at 30 V input voltage (ac or dc)

Battery Charging

-NOTA- The "T" represents temperature in degrees Celsius.
FLOAT Charging Vbatt(T) = 13.65 V - (24 mV) x (T - 25) + (0.24 mV) x (T - 25)2
Precisión ±1% (on charging voltage over -40° to +60°C)

Power Out (+12 Terminals)

Voltaje Unregulated 12 V from battery (4.65 A solid-state circuit breaker)
Standards ETL Listed Class 2 power supply

Compatibilidad

Nota: lo siguiente muestra información de compatibilidad notable. No es una lista de todos los productos compatibles.

Dataloggers

Producto Compatible Nota
CR1000 (retired)
CR200X (retired)
CR216X (retired)
CR3000 (retired) Typically, a CR3000 datalogger uses its integrated rechargeable base instead of the PS150. However, the PS150 can be used if the data logger has a low-profile base or if the battery base has been disconnected.
CR5000 (retired) Typically, a CR5000 datalogger uses its integrated rechargeable base instead of the PS150. However, the PS150 can be used if the data logger has a low-profile base or if the battery base has been disconnected.
CR6
CR800 (retired)
CR850 (retired)
CR9000X (retired)

Fuentes Alimentación

Producto Compatible Nota
SP10
SP40

Equipos para montajes

Producto Compatible Nota
ENC10/12
ENC12/14
ENC14/16
ENC16/18

Miscelaneo

Producto Compatible Nota
34029

Información de compatibilidad adicional

Solar Panels

SP5-L SP10 SP10R SP20 SP20R SP50-L SP90-L

Datalogger Considerations

Compatible Contemporary Dataloggers

CR200(X) Series CR800/CR850 CR1000 CR3000 CR9000X CR6
*

Compatible Retired Dataloggers

CR500 CR510 CR10 CR10X 21X CR23X CR5000 CR7X CR9000
* *

Note:
*Typically, a CR23X, CR3000, or CR5000 datalogger uses its integrated rechargeable base instead of the PS150. However, the PS150 can be used if the datalogger has a low-profile base or if the battery base has been disconnected.

Enclosure Considerations

A desiccated, non-condensing environment is required. The PS150 includes built-in keyhole flanges for mounting to the backplate of a Campbell Scientific enclosure.

Compatible Enclosures

ENC10/12 ENC10/12R ENC12/14 ENC14/16 ENC16/18

Adapters

The PS150 is compatible with the A100 null-modem adapter and the A105 adapter for additional 12 V output terminals. The A100 Null Modem Adapter connects and powers two Campbell Scientific peripherals via two CS I/O 9-pin connectors configured as a null modem. This is useful in linking different communications technologies, such as telephone to radio, at sites that do not have a datalogger. The A105 adapter may be used to provide additional 12 V and ground terminals where the power supply is used to power several devices.


Preguntas frecuentes

Número de FAQs relacionadas con PS150: 5

Expandir todoDesplegar todo

  1. The PS100, PS150, and PS200 models take in AC or DC power from a wall transformer or a solar panel. The internal regulator controls the charge to the battery to make sure the battery doesn’t become overcharged (based on temperature).

    If the switch is on, the voltage from the battery will flow back out from the regulated battery to the loads; however, the voltage on that battery may be 11.9 V, 13.2 V, or some other value that the battery happens to be at. It is important to understand that the voltage will not always be exactly 12.0 Vdc. Rather, the voltage will float up or down as the battery is recharged or depleted.

  2. The voltage from a solar panel will fluctuate throughout the day.

    If AC power is being used, the voltage is usually stable. 

    The voltages coming into the regulator inputs are controlled so that the battery won’t be overcharged (and thus ruined by boiling out the electrolyte). If the battery connected to the regulator is good, the highest voltage you will likely see is just above 14 Vdc in the extreme cold, but normally it should be around 13.2 Vdc. 

    If you have a nearly dead battery (to be checked with a voltmeter) or a battery with shorted cells, you will see a very low battery voltage. The lowest voltage you will see on the data logger data is usually about 10.0 V because the data logger will shut down near that level and then wait for the voltage to increase to an 11- or 12-volt level.

    The ripple voltage is a few millivolts flowing into the battery, but the battery should filter out most of that noise, providing a pretty stable voltage.

  3. Yes. The G and 12V terminals on the charge regulator are used to connect the black and red wires that connect with the green connector, which provides power to the data logger.

  4. Look for a stamp on top of the battery. The stamp should be in a date format of YYMMDDXX where:

    • YY is the year.
    • MM is the month.
    • DD is the day.
    • XX is the manufacturing plant.

    This indicates the age of the battery.

    To evaluate the condition of the battery:

    1. Charge the battery.
    2. Let the battery sit for a couple of hours.
    3. Measure the open circuit voltage to get an estimated indication of condition.
  5. The CH150 or PS150 will pull power only from the source with the highest voltage at that moment. For example, the regulator will take the 20 W input from the 24 Vdc wall transformer rather than from the 18 V 50 W solar panel—even during the day. If the power goes out, the 50 W solar panel will charge during the day with no charging at night.

Casos de aplicación

Egypt: Preserving King Tut's Tomb
In 1922, when the tomb of Tutankhamen was discovered in Egypt's Valley of the Kings,......leer más

Artículos y notas de prensa

Figura en

Replacement Part for the following products: