DESCATALOGADO ›
Este producto ya no está disponible. Algunos accesorios, recambios o servicios pueden todavía estar disponibles.

Imagen no disponible

Services Available
Free Support No

Resumen

Versión actual: 2.1

El PC-OPC/10 es un pack de 10 licencias del software PC-OPC, con un precio reducido por copia. Este pack está pensado para aplicaciones en que haya múltiples ordenadores de la red que requieran presentar datos del servidor Loggernet mediante protocolo OPC.

El servidor PC-OPC permite a paquetes gráficos del mercado que sean compatibles con el protocolo OPC, poder mostrar datos del datalogger o dataloggers disponibles en la memoris caché de Loggernet.

Leer más

Descripción detallada

PC-OPC/10 provides ten licenses of PC-OPC at a reduced cost per copy. It is intended to allow data to be transferred from a LoggerNet server to multiple client computers.

The PC-OPC server provides a standard interface that allows third-party OPC-compatible graphics packages to display the datalogger data. Specifically, the PC-OPC Server:

  • Provides data via “data tags” to any SCADA or third-party soft ware that supports OPC
  • Updates, or pushes, data to third-party software as the LoggerNet server collects it from the datalogger(s)
  • Allows third-party software to set input locations, variables, ports, and flags in our dataloggers

Especificaciones

Current Version 2.1
Data Access Standard Supports Data Access Standard 2.05a only.
Requirement Licensed copy of LoggerNet or LoggerNetAdmin must be running on the same PC or a remote PC that is accessible via TCP/IP.
Purchased Separately Yes
Dimensions 12.7 x 14.0 x 0.33 cm (5.0 x 5.5 x 1.3 in.)
Weight 453.6 lb (1.0 lb)

Compatibilidad

Nota: lo siguiente muestra información de compatibilidad notable. No es una lista de todos los productos compatibles.

Dataloggers

Producto Compatible Nota
CR1000 (retired)
CR1000X
CR200X (retired)
CR216X (retired)
CR300
CR3000 (retired)
CR3000 (retired)
CR3000 (retired)
CR3000 (retired)
CR310
CR5000 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR9000X (retired)

Miscelaneo

Producto Compatible Nota
21X (retired) The 21X requires three PROMs; two PROM 21X Microloggers are not compatible.
CR10 (retired)
CR10X (retired) LoggerNet is compatible with the mixed array, PakBus, and TD operating systems.
CR23X (retired) LoggerNet is compatible with the mixed array, PakBus, and TD operating systems.
CR500 (retired)
CR510 (retired) LoggerNet is compatible with the mixed array, PakBus, and TD operating systems.
CR9000 (retired)

Información de compatibilidad adicional

Requires a licensed copy of LoggerNet running on the same PC or a remote PC that is accessible via TCP/IP.

OPC Products

Many software and hardware products support OPC. Products that have been tested by Campbell Scientific include Iconics Genesis, Intellution IFIX, and National Instruments Lookout. PC-OPC supports Data Access Standard 2.05a only.

Computer

Minimum recommended hardware is 300 MHz Pentium II processor with 128 Mbyte of RAM and screen resolution of 800 x 600. Recommended computer operating systems are Windows Vista, 2000, and XP.

Preguntas frecuentes

Número de FAQs relacionadas con PC-OPC/10: 5

Expandir todoDesplegar todo

  1. The PC-OPC Server works with OPC Data Access Specification 2.05a.

  2. The PC-OPC Server demo enables users to verify if an OPC client will work with Campbell Scientific’s OPC server. The trial version doesn't actually connect to a LoggerNet server or provide any true data. It only provides mock data.

  3. If the OPC client software supports getting data from an SQL server, LoggerNet Database Software (LNDB) may be a more appropriate option than PC-OPC. LNDB stores a complete history of data tables retrieved from the dataloggers in an SQL server. In contrast, PC-OPC only provides the last record from each data table in the LoggerNet cache when it is first started and any new records that are collected by LoggerNet while the PC-OPC Server is running. If the OPC client is storing PC-OPC data in its own database, gaps will be created (missing data) in the OPC client database if the PC-OPC Server, the OPC client, or both are not running when LoggerNet collects the data.

  4. The blog article "How to Navigate the World of Software Upgrades, Patches, and Trials" explains the difference between patches (free of charge) and upgrades (for a fee). This example quickly shows the difference between an upgrade and a patch:

    Upgrade Patch

    Major version change, such as 1.3 to 2.0

    Minor version change, such as 1.3 to 1.4

    Typically requires purchase for a fee

    Free of charge

  5. Campbell Scientific dataloggers cannot communicate directly with LabVIEW. However, after retrieving data collected by any of the Campbell Scientific dataloggers and placing the data in the LoggerNet data cache, the data can be shared with LabVIEW using a LoggerNet client called PC-OPC. A trial version of PC-OPC is available in the Downloads section of the PC-OPC product page.  

    The PC-OPC Server software provides a standard interface that allows third-party OPC-compatible graphics packages, including LabVIEW, to display the datalogger data.

    In addition to using the PC-OPC Server and the data socket feature in LabVIEW, communication can also be established using LoggerNet-SDK with ActiveX controls.

Figura en

Otros accesorios para los productos siguientes: