Sensores / Velocidad y dirección del viento
Velocidad y dirección del viento

Gama de productos

Measurement Description Operating Temperature Range Starting Threshold Accuracy

05103

Wind speed and direction -50° to +50°C (assuming non-riming conditions)
  • Wind Speed: 1.0 m/s (2.2 mph)
  • Wind Direction: 1.1 m/s (2.4 mph) at 10° displacement
  • Wind Speed: ±0.3 m/s (±0.6 mph) or 1% of reading
  • Wind Direction: ±3°

CSAT3B

Highest-quality wind speed and direction -40 to +50°C (equivalent to 305 to 368 m s-1 in speed of sound)

CSAT3BH

Highest-quality wind speed and direction -40 to +50°C (equivalent to 305 to 368 m s-1 in speed of sound)

WINDSONIC4

Wind speed and direction -35° to +70°C
  • Wind Direction: ±3°
  • Wind Speed: ±2% (@ 12 m/s)

03002

Wind speed and direction -50° to +50°C (assuming non-riming conditions)
  • Wind Speed (Anemometer): 0.5 m/s (1.1 mph)
  • Wind Direction (Vane): 0.8 m/s (1.8 mph) with 10° displacement
  • Wind Direction (Vane): 1.8 m/s (4 mph) with 5° displacement
  • Wind Speed (Anemometer): ±0.5 m/s (1.1 mph)
  • Wind Direction (Vane): ±5°

05108-45-L

Wind speed and direction -50° to +60°C (assuming non-riming conditions)
  • Wind Speed: 1.0 m/s (2.2 mph)
  • Wind Direction: 1.0 m/s (2.2 mph) at 10° displacement
  • Wind Speed: ±0.3 m/s (±0.6 mph) or 1% of reading
  • Wind Direction: ±3°

05305-L

Wind speed and direction -50° to +50°C (assuming non-riming conditions)
  • Wind Speed: 0.4 m/s (0.9 mph)
  • Wind Direction: 0.5 m/s (1.0 mph) at 10° displacement
  • Wind Speed: ±0.2 m/s (±0.4 mph) or 1% of reading
  • Wind Direction: ±3°

WINDSONIC1

Wind speed and direction -35° to +70°C
  • Wind Direction: ±3°
  • Wind Speed: ±2% (@ 12 m s-1)

014A

Wind speed -50° to +70°C 0.45 m/s (1.0 mph) 0.11 m/s (0.25 mph) or 1.5%

ICEFREE3A

27106T

Vertical wind speed -50° to +50°C

A100LK-L

Wind speed -30° to +70°C 1% ±0.1 ms-1

ICEFREE3V

034B

Wind speed and direction -30° to +70°C Wind Speed (Anemometer): 0.4 m/s (0.9 mph)
  • Wind Speed (Anemometer): 0.1 m/s (0.25 mph) at < 10.14 m/s (22.7 mph)
  • Wind Speed (Anemometer): ±1.1% of true at > 10.14 m/s (22.7 mph)
  • Wind Direction (Vane): ±4°

05106

-50° to +50°C (assuming non-riming conditions)
  • Wind Speed: 1.1 m/s (2.4 mph)
  • Wind Direction: 1.1 m/s (2.4 mph) at 10° displacement
  • Wind Speed: ±0.3 m/s (0.6 mph) or 1% of reading
  • Wind Direction: ±3°

Otros

Measurement Description Operating Temperature Range Starting Threshold Accuracy

05108-L

Wind speed and direction -50° to +60°C (assuming non-riming conditions)
  • Wind Speed: 1.0 m/s (2.2 mph)
  • Wind Direction: 1.0 m/s (2.2 mph) at 10° displacement
  • Wind Speed: ±0.3 m/s (±0.6 mph) or 1% of reading
  • Wind Direction: ±3°

P2546D-L

Wind speed Switching Characteristics: -40° to +60°C < 0.3 m/s

P2546C-L

Wind speed Switching Characteristics: -35° to +60°C < 0.4 m/s

Preguntas frecuentes

Número de FAQs relacionadas con Velocidad y dirección del viento: 2

  1. Sometimes, an old cable can be replaced with a new, shorter cable.

    Sometimes, an existing cable can be shortened by cutting the ends off. However, there are a few issues that could be encountered when doing this:

    • Some sensors have bridge completion resistors at the pigtail end.
    • Some sensors are calibrated to length.
    • Sometimes the color in the insulation may not be the same as that visible at the pigtail end.

    Because of the potential issues, do not cut the ends off any sensor cable without first contacting Campbell Scientific to discuss the sensor in detail.

  2. Many times, but not always, a sensor’s cable can be replaced with a new cable. This is helpful if the original cable was damaged or if its length needs to be changed.

    If the cable is attached to the sensor using a connector, Campbell Scientific will sell a replacement cable. For example, a 05106CBL-L is a replacement cable for a 05106-L. Replacement cables are listed in the “Replacement Parts” section of the Ordering information area of the product page.

    If the cable is attached to a sensor through a user-accessible terminal block, a raw cable can be purchased to replace it. For example, to replace the cable on a 05103-L Wind Monitor, order the desired length of pn 972124 AWG 3 Twisted Pair Shielded Santoprene Cable. As another example, the raw cable for a TE525-L Rain Gage is pn 966122 AWG 1 Twisted Pair Shielded Santoprene Cable.

    If the cable is an integral part of the sensor, the cable cannot be user replaced, and the sensor must be returned to Campbell Scientific. Some examples of sensors that fall into this category include the 107-L, 109SS-L, 229-L, CS547A-L, and CS650-L. For the process of returning equipment to Campbell Scientific, refer to the Repair and Calibration page.