Sensores / Temperatura y humedad relativa del aire
Temperatura y humedad relativa del aire

Gama de productos

Sensing Element Measurement Range Accuracy Field-Replaceable Chip or Recalibrate

HygroVue 10

SHT35 modified by Campbell Scientific
  • Relative Humidity: 0 to 100% RH
  • Air Temperature: -40°C to +70°C
  • Relative Humidity: -NOTE- The accuracy figures quoted are the 95% confidence limits relative to factory standards.
  • Relative Humidity: ±1.5% (at 25°C, over the range 0 to 80% RH)
  • Relative Humidity: ±2% (at 25°C, over the range 80 to 100% RH)
  • Air Temperature: ±0.2°C (over the range -40 to +70°C)
  • Air Temperature: ±0.1°C (over the range 20 to 60°C)
Field-replaceable chip

HygroVue 5

SHT35 derivative (specially coated for reliability)
  • Air Temperature: -40 to +70°C
  • Relative Humidity: 0 to 100% RH
  • Air Temperature: ±0.4°C (over the range -40 to +70°C)
  • Air Temperature: ±0.3°C (over the range 20 to 60°C)
  • Relative Humidity: ±1.8% (at 25°C, over the range 0 to 80% RH)
  • Relative Humidity: ±3% (at 25°C, over the range 80 to 100% RH)
Field-replaceable chip

EE181

  • Air Temperature: 1000 Ω Platinum Resistance Thermometer (PRT)
  • Relative Humidity: Capacitance
  • Air Temperature: -40° to +60°C
  • Relative Humidity: 0 to 100% RH (non-condensing)
  • Air Temperature: ±0.2°C (at +23°C)
  • Relative Humidity: -NOTE- Accuracy specifications include hysteresis, non-linearity, and repeatability.
  • Relative Humidity: ±(1.3 + 0.003 • RH reading) % RH (at -15° to +40°C, 0 to 90% RH)
  • Relative Humidity: ± 2.3% RH (at -15° to +40°C, 90 to 100% RH)
  • Relative Humidity: ± (1.4 + 0.01 • RH reading) % RH (at -25° to +60°C)
  • Relative Humidity: ± (1.5 + 0.015 • RH reading) % RH (at -40° to +60°C)

HMP155A-L

  • Relative Humidity: HUMICAP 180R
  • Air Temperature: PT 100 RTD 1/3 class B IEC 751
  • Relative Humidity: 0 to 100% RH (non-condensing)
  • Air Temperature: -80° to +60°C
  • Relative Humidity: -NOTE- Accuracy specifications include non-linearity, hysteresis, and repeatability.
  • Relative Humidity: ±1% RH (at 15° to 25°C, 0 to 90% RH)
  • Relative Humidity: ±1.7% RH (at 15° to 25°C, 90 to 100% RH)
  • Relative Humidity: ±(1.4 + 0.032 × reading) % RH (at -60° to -40°C)
  • Relative Humidity: ±(1.2 + 0.012 × reading) % RH (at -40° to -20°C)
  • Relative Humidity: ±(1.0 + 0.008 × reading) % RH (at -20° to +40°C)
  • Relative Humidity: ± (1.2 + 0.012 × reading) % RH (at 40° to 60°C)
  • Air Temperature: ±(0.226 - 0.0028 x temperature)°C (-80° to +20°C)
  • Air Temperature: ±(0.055 + 0.0057 x temperature)°C (+20° to +60°C)
Recalibrate

HMP60

  • Relative Humidity: Vaisala’s INTERCAP capacitive chip
  • Air Temperature: 1000 ohm Platinum Resistance Thermometer (PRT)
  • Relative Humidity: 0 to 100% RH (non-condensing)
  • Air Temperature: -40° to +60°C
Air Temperature: ±0.6°C Field-replaceable chip (RH only)

Wintersense

  • Road-Surface Temperature: -40 to +70°C (-40 to +158°F)
  • Dew Point Temperature (Calculated): -40 to +70°C (-40 to +158°F)
  • Air Temperature: -40 to +70°C (-40 to +158°F)
  • Relative Humidity: 0 to 100%
  • Dew Point Temperature (Calculated): ±1°C
  • Dew Point Temperature (Calculated): Note: The calculated dew point temperature is found from Tetens' equation solved for dew point with coefficients optimized for the temperature range -35 to +50°C.
  • Air Temperature: ±0.4°C
  • Air Temperature: Note: Inaccuracy can be higher under moderate-to-high solar radiation.
  • Relative Humidity: < ±3%

Documentos

Preguntas frecuentes

Número de FAQs relacionadas con Temperatura y humedad relativa del aire: 2

  1. Sometimes, an old cable can be replaced with a new, shorter cable.

    Sometimes, an existing cable can be shortened by cutting the ends off. However, there are a few issues that could be encountered when doing this:

    • Some sensors have bridge completion resistors at the pigtail end.
    • Some sensors are calibrated to length.
    • Sometimes the color in the insulation may not be the same as that visible at the pigtail end.

    Because of the potential issues, do not cut the ends off any sensor cable without first contacting Campbell Scientific to discuss the sensor in detail.

  2. Many times, but not always, a sensor’s cable can be replaced with a new cable. This is helpful if the original cable was damaged or if its length needs to be changed.

    If the cable is attached to the sensor using a connector, Campbell Scientific will sell a replacement cable. For example, a 05106CBL-L is a replacement cable for a 05106-L. Replacement cables are listed in the “Replacement Parts” section of the Ordering information area of the product page.

    If the cable is attached to a sensor through a user-accessible terminal block, a raw cable can be purchased to replace it. For example, to replace the cable on a 05103-L Wind Monitor, order the desired length of pn 972124 AWG 3 Twisted Pair Shielded Santoprene Cable. As another example, the raw cable for a TE525-L Rain Gage is pn 966122 AWG 1 Twisted Pair Shielded Santoprene Cable.

    If the cable is an integral part of the sensor, the cable cannot be user replaced, and the sensor must be returned to Campbell Scientific. Some examples of sensors that fall into this category include the 107-L, 109SS-L, 229-L, CS547A-L, and CS650-L. For the process of returning equipment to Campbell Scientific, refer to the Repair and Calibration page.