		The SR30-L, an ISO 9060:2018 spectrally flat Class A (secondary standard) pyranometer manufactured by Hukseflux, features Recirculating Ventilation and Heating (RVH™) technology. As a standalone unit, the SR30-L is fully compliant with IEC 61724-1 standards, whereas other pyranometers would require external ventilation/heating units to be compliant. The SR30-L is an ideal instrument for solar resource and PV performance monitoring.
 
				 
							 
							 
							 
							 
							 
							 
							| Sensor | High-quality blackened thermopile protected by two glass domes with integrated heater and ventilation | 
| Measurement Description | Monitors solar radiation for the full solar spectrum range | 
| Hemispherical Solar Radiation | |
| Heater | RVH™ (Recirculating Ventilation and Heating) | 
| ISO Classification | Spectrally flat Class A (secondary standard) ISO 9060:2018 | 
| IEC 61724-1:2021 Compliance | Class A | 
| Calibration Uncertainty | < 1.2% (k = 2) | 
| Heating | Included | 
| Ventilation | Included | 
| Technology Employed | Recirculating Ventilation and Heating (RVH™) | 
| Standard Operating Mode | Heated and ventilated | 
| Power Consumption @ 12 Vdc | < 2.3 W | 
| Zero Offset A | < 2 W/m2 | 
| Calibration Traceability | To WRR | 
| Calibration Registers | Accessible to users | 
| Spectral Range | 285 to 3000 x 10-9 m | 
| Sensitivity | Digital output | 
| Operating Temperature Range | -40 to +80°C (rated) | 
| Temperature Response | < ±0.4% (-30 to +50°C) | 
| Temperature Response Test of Individual Instrument | Report included | 
| Directional Response Test of Individual Instrument | Report included | 
| Rated Operating Voltage Range | 8 to 30 Vdc | 
| Sensor Tilt Angle | |
| Tilt Measurement Uncertainty | ±1° (0 to 90°) | 
| Tilt Sensor Test of Individual Instrument | Report included | 
| Operation in Low-Power Mode | |
| Operating Condition | Heater and ventilator [OFF] | 
| Zero Offset A | 5 W/m2 (unventilated) | 
| Power Consumption @ 12 Vdc | < 0.1 W | 
| Digital Output | |
| Output | 
 | 
| Communication Protocol | Modbus over two-wire RS-485 | 
| Transmission Mode | RTU | 
The example CR1000X program measures the SR30 sensor. The program will store the values if the result code is zero, which indicates a properly working sensor. If the result code is not zero, NANs will be stored for the measurements.