SN500SS Net Radiometer
Digital, Low-cost Net Radiometer
meteorología aplicaciones agua aplicaciones energía aplicaciones flujo gas y turbulencia aplicaciones infraestructuras aplicaciones suelo aplicaciones

Resumen

This four-component net radiometer, manufactured by Apogee Instruments, provides individual measurement of net radiation components. This sensor features an SDI-12 output, eliminating the need for multiple analog channels to measure the individual components of net radiation. The SN500SS offers a complete package that includes a net radiometer, mounting rod, pigtail lead cable for data logger interface, and a carrying case.

Imágenes


Especificaciones

Sensor Two thermopile pyranometers, two pyrgeometers
Measurement Description Measures incoming and outgoing short-wave and long-wave radiation
Heater 62 mA current drain and 740 mW power requirement at 12 Vdc
Operating Temperature Range -50° to +80°C and 0 to 100% humidity
Response Time 1 s (SDI-12 data transfer rate; detector response times are 0.5 s)
Heater Current Drain
  • 63 mA (heaters on; communication enabled)
  • 1.5 mA (heaters off; communication enabled)
  • 0.6 mA (heaters off; communication disabled)
Dimensions 11.6 x 4.5 x 6.6 cm (4.6 x 1.8 x 2.6 in.)
Weight 320 g (11.29 oz) with mounting rod and 5 m (16.4 ft) of lead wire

Pyranometer

Spectral Range
  • 385 to 2105 nm (upward-looking)
  • 295 to 2685 nm (downward-looking)
Sensitivity
  • 0.057 mV per W/m2 (upward-looking)
  • 0.15 mV per W/m2 (downward-looking)
Expected Output Range
  • 0 to 114 mV (upward-looking)
  • 0 to 300 mV (downward-looking)

Pyrgeometer

Spectral Range 5,000 to 30,000 nm
Sensitivity 0.12 mV per W/m2
Expected Output Range -24 to +24 mV

Compatibilidad

Nota: lo siguiente muestra información de compatibilidad notable. No es una lista de todos los productos compatibles.

Dataloggers

Producto Compatible Nota
CR1000 (retired)
CR1000X
CR300
CR3000 (retired)
CR310
CR350
CR6
CR800 (retired)
CR850 (retired)
CRVW3
CRVW3-NE

Descargas

SN500SS Program Example (1 KB) 11-08-2021

An example program that uses the M! SDI-12 command to measure the incoming short-wave (SW) radiation, outgoing SW radiation, incoming long-wave (LW) radiation, and outgoing LW radiation of the SN500SS. The example program supports the CR6 and CR1000X data loggers.


Casos de aplicación

United Kingdom: Pioneering Research in Carbon Sequestration
Overview In the fight against climate change, innovative solutions are emerging to address the global challenge......leer más
South Africa: Sustainable Solutions for Farms
International partnerships for sustainable innovations Improved water use in agriculture is essential to successfully adapt to......leer más

Artículos y notas de prensa

Figura en

Common Accessory for the following products: