The 29847 is a calibration service, provided at the factory, for the HMP155A. All factory recalibrations require an RMA (Return Material Authorization).
Leer másSolar panels are photovoltaic power sources capable of recharging batteries. The minimum battery size and solar panel output required depends on 1) the average current drain of the system, 2) the maximum time the battery must supply power to the system without being charged, and 3) the location of the site. If you need assistance in selecting a solar panel, refer to our Power Supplies brochure, application note, or contact a Campbell Scientific Applications Engineer.
Solar panel characteristics assume 1 kW m-2 illumination and 25°C solar panel temperature. Individual panels may vary up to 10%. The output panel voltage increases as the panel temperature decreases. All solar panels are shipped with hardware for mounting to a tripod or tower.
The SP60 solar panel is used for our CS110 Electric Field Meter or other systems that require 60 W solar panels. It needs to be connected to either a CH200 Smart Charge Controller or 008116 Morningstar SunSaver regulator.
The SP60 is not compatible with PS100E-LA, PS100, PS200, CR3000 with battery base. The CH200 charger is normally used to charge larger batteries (24 Ah minimum but bigger than this is recommended). In sunny areas where the full output of the panel is possible then the Morningstar Regulator should be used.
|
|
SP5 |
SP10 |
SP30 |
SP60 |
SP100
|
|
Typical peak power (W) |
4.5(±10%) |
10(±10%) |
30(+/-5%) |
60(+/-5%) |
100(+/-5%)
|
|
Voltage at peak power** |
16.5 |
16.8 |
17.5 |
17.5 |
18.0
|
|
Current at peak power (A) |
0.27 |
0.57 |
1.68 |
3.43 |
5.56
|
|
Short circuit current (A) |
0.30 |
0.6 |
1.88 |
3.84 |
6.06
|
|
Open circuit voltage** |
20.5 |
21.0 |
21.0 |
21.6 |
21.6
|
|
Dimensions (excluding bracket) |
251x269 mm |
420x269 mm |
415x510 mm |
535x734 mm |
1037x527 mm
|
|
Weight (excluding bracket) |
0.9kg |
1.9kg |
2.95kg |
5.8kg |
7.4kg
|
|
Temp. coeff . of voltage (mV/°C) |
-80 |
-72 |
-63 |
-61 |
-61
|
|
Temp. coeff . of power (%/°C) |
-0.5 |
-0.37 |
-0.38 |
-0.38 |
-0.38
|
|
Cable *** termination |
Fixed 4.5m lead |
Fixed 4.5m lead |
5m lead with MC3 Connectors |
5m lead with MC3 Connectors |
5m lead with MC3 Connectors |
*Power ratings are obtained under standard test conditions of 1000 Wm-2 and 25°C cell temperature.
**These are voltages at the panel surface. If an external regulator or long cables are used the apparent output voltage will be lower.
***Larger panels have two separate output leads fitted with MC3 connectors. A single dual-core extension cable is supplied with mating connectors to make
the standard total cable length 5m.