Reguladores / CH150
CH150 12 V Charging Regulator
ETL-Listed Charging Regulator
meteorología aplicaciones agua aplicaciones energía aplicaciones flujo gas y turbulencia aplicaciones infraestructuras aplicaciones suelo aplicaciones

Resumen

The CH150 is a charging regulator for an external rechargeable 12 V VRLA (valve-regulated lead-acid) battery, such as the BP12 or BP24 offered by Campbell Scientific. Charging power for the CH150 is typically supplied by an unregulated solar panel, AC/AC transformer, or AC/DC converter. The CH150 provides charging with temperature compensation for optimal charging and battery life. A maximum power point tracking algorithm is incorporated for solar inputs to maximize available solar charging resources.

The CH150 is ETL certified. The ETL Mark is proof of product compliance to North American safety standards.

Leer más

Ventajas y características

  • Protege contra daños por alto amperaje y alto voltaje
  • Protección contra polaridad invertida de la batería
  • Permite la conexión simultanea de dos fuentes de carga (por ej. panel solar y adaptador 220Vac)
  • Fuente alimentación ETL listed Class 2
  • Disponible extensión garantía de 3 años

Imágenes

CH150 front view
CH150 front view
CH150 front view
CH150 back view
CH150 left view
CH150 right view
CH150 top view
CH150 bottom view

Descripción detallada

The CH150 is a micro-controller-based smart charger with temperature compensation that optimizes battery charging and increases the battery's life. Two input terminals enable simultaneous connection of two charging sources. They also incorporate a maximum power point tracking algorithm for solar inputs that maximizes available solar charging resources.

The CH150 has several safety features intended to protect the charging source, battery, charger, and load devices. Battery-reversal protection is included, as well as ESD and surge protection on all of the CH150 inputs and outputs.

The CH150 replaced the CH100. 

Especificaciones

Operational Temperature -40° to +60°C (VRLA battery manufacturers state that “heat kills batteries” and recommend operating batteries at ≤ 50°C.)
Dimensiones 7.5 x 3.7 x 10.0 cm (3 x 1.5 x 3.9 in.)

CHARGE - CHARGE Terminals (AC or DC Source)

AC 18 to 24 VRMS (internally limited to 1.2 ARMS)
DC 16 to 40 Vdc (internally limited to 0.85 Adc)

SOLAR Terminals (Solar Panel or Other DC Source)

-NOTA- Battery voltages below 8.7 V may result in < 3.0 A current limit because of fold-back current limit.
Rango voltaje entrada 15 to 40 Vdc
Maximum Charging Current 4.0 Adc typical (3.2 to 4.9 Adc depending upon individual charger)

Quiescent Current

No Charge Source Present 160 μA at 13.7 Vdc
No Battery Connected 930 μA at 30 volt input voltage (ac or dc)

Battery Charging

-NOTA- The "T" represents temperature in degrees Celsius.
FLOAT Charging Vbatt(T) = 13.65 V - (24 mV) x (T - 25) + (0.24 mV) x (T - 25)2
Precisión ±1% (on charging voltage over -40° to +60°C)

Power Out (+12 Terminals)

Voltaje Unregulated 12 V from battery (4.65 A solid-state circuit breaker)
Standards ETL Listed Class 2 power supply

Compatibilidad

Nota: lo siguiente muestra información de compatibilidad notable. No es una lista de todos los productos compatibles.

Dataloggers

Producto Compatible Nota
CR1000 (retired)
CR200X (retired)
CR216X (retired)
CR3000 (retired) Typically, a CR3000 datalogger uses its integrated rechargeable base instead of the CH150. However, the CH150 can be used if the data logger has a low-profile base or if the battery base has been disconnected.
CR5000 (retired) Typically, a CR5000 datalogger uses its integrated rechargeable base instead of the CH150. However, the CH150 can be used if the data logger has a low-profile base or if the battery base has been disconnected.
CR6
CR800 (retired)
CR850 (retired)
CR9000X (retired)

Fuentes Alimentación

Producto Compatible Nota
SP10
SP40

Miscelaneo

Producto Compatible Nota
21X (retired)
34029
CR10 (retired)
CR10X (retired)
CR23X (retired) Typically, a CR23X datalogger uses its integrated rechargeable base instead of the CH150. However, the CH150 can be used if the data logger has a low-profile base or if the battery base has been disconnected.
CR500 (retired)
CR510 (retired)
CR9000 (retired)

Información de compatibilidad adicional

Enclosure Considerations

A desiccated, non-condensing environment is required. The CH150 includes built-in keyhole flanges for mounting to the backplate of a Campbell Scientific enclosure.

Adapters

The CH150 is compatible with the A100 null-modem adapter and the A105 adapter for additional 12 V output terminals. The A100 Null Modem Adapter connects and powers two Campbell Scientific peripherals via two CS I/O 9-pin connectors configured as a null modem. This is useful in linking different communications technologies, such as telephone to radio, at sites that do not have a datalogger. The A105 adapter may be used to provide additional 12 V and ground terminals where the power supply is used to power several devices.


Preguntas frecuentes

Número de FAQs relacionadas con CH150: 1

  1. The CH150 or PS150 will pull power only from the source with the highest voltage at that moment. For example, the regulator will take the 20 W input from the 24 Vdc wall transformer rather than from the 18 V 50 W solar panel—even during the day. If the power goes out, the 50 W solar panel will charge during the day with no charging at night.


Artículos y notas de prensa

Figura en

Otros accesorios para los productos siguientes: